  radiometrix ltd RMX2-433-10 data sheet pa ge 1/12 figure 1: RMX2-433-10 features +10dbm (10mw) rf power, 3.0v @ 35ma operation programmable rf channel fast tx/rx switching time (5ms) receiver sensitivity -119dbm class one receiver performance etsi en 300 220-3, en 301 489-3 compliant RMX2 is a narrowband multichannel module with 25 khz channel steps, but still achieves sub-10ms tx/rx switching speed, making it an ideal rf unit for inclusion in feedback systems. the narrow band technique used in RMX2 enables high interference rejection and concurrent operation with multiple modules. applications telemetry water level monitor for rivers, dams, etc. monitoring systems for environmental data such as temperature, humidity, etc. transmission of measurement data (pressure, revolution, current, etc) to pc security alarm monitoring telecontrol industrial remote control systems remote control systems for factory automation machines narrow band direct interface multi channel transceiver narrow band direct interface multi channel transceiver narrow band direct interface multi channel transceiver narrow band direct interface multi channel transceiver the RMX2 is an etsi en 300 220-3 com p liant uhf fm narrow ban d semi-duplex radio data module. it i s a hi g h p er f ormance transceive r desi g ned f or use in industria l a pp lications re q uirin g lon g ran g e, high performance and reliability. the o p eratin g f re q uencies ar e available in the 433.05-434.79mh z e uro p ean ism band and 458.5- 459.1mhz uk srd band allocations. radiometrix hartcran house, 231 kenton lane, harrow, ha3 8rp, england issue 1, 01 november 2007 RMX2 n e w tel: +44 (0) 20 8909 9595, fax: +44 (0) 20 8909 2233 preliminary data sheet www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 2/12 figure 2: RMX2 block diagram www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 3/12 50 3 12 22.5 18 9.67 12.7 22.5 18 15.24 7.13 7.13 30 2.54 2.5 0.7 2.54 clk data le ld rssi d0 d1 92.5 5.1 1 2.5 rxm2-433-10 uhf multi channel narrow band transceiver recommended pcb hole size: 1.2 mm reference hole position for pcb mounting (bottom view) module footprint size: 30 x 50 mm pin pitch: 2.54 mm figure 3: pinouts and dimensions www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 4/12 condensed specifications all ratings at 25c unless otherwise noted parameter rating conditions general characteristics operating frequency range 433.05 - 434.775 mhz european ism band (RMX2-433-10) 458.5-459.1mhz uk srd allocation (RMX2-458-10) channel step programmable (pll ic: fujitsu mb15e03sl) frequency stability 3ppm -20 to +70 c data rate 9600 bps max input data pulse width: min 104s, max 5ms pll reference frequency 21.25 mhz operating voltage range 3 ? 15 v supply current 35ma (tx) 24ma (rx) operating temperature range - 20 to + 70 c dimensions 30 x 50 x 9 mm transmitter section rf output power 10mw 1db at 434.0mhz / 458.7mhz, antenna impedance 50 ? deviation (digital in) 2.4khz 0.3khz pn9, 9600 bps, lpf 20 khz deviation frequency characteristics 3db dc to 4800hz tx s/n -30db 1khz, deviation = 2.4khz ccitt filter spurious emission <-54dbm <1ghz, non-harmonic spurii <-40dbm 2nd and 3rd harmonics adjacent channel leakage power -37dbm ch 25khz, bw = 16khz, pn9, 9600 bps total distortion and noise 30db 1khz, deviation = 2.4khz, ccitt filter switching time rx to tx 5 - 10ms rx tx * 1 lock time 30 ? 40ms free run tx * 2 10 ? 20ms 25khz channel shift * 3 receiver section receiver sensitivity -119dbm (af out) 1khz, deviation 2.4khz, ccitt filter receiver s/n 35db 1khz, deviation 2.4 khz, ccitt filter, rf level = -30dbm distortion 5% 1khz, deviation 2.4khz, ccitt filter, rf level=- 30dbm all spurious responses better than 60db 2 signal method, jamming signal = fm intermodulation better than 50db 2 signal method adjacent channel selectivity 65db 2 signal method, 25khz jamming signal = fm blocking >84dbm 1, 2, 5, 10 mhz switching time tx to rx 5 - 10 ms tx rx * 1 lock time 30 - 40 ms free run rx * 2 10 - 20 ms 25khz channel shift * 3 notes: 1. time until tx frequency or 1st local frequency reach a steady frequency 1.5ppm 2. time until tx frequency or 1st local frequency reach a steady frequency 1.5ppm after pll setting data is set. 3. time until tx frequency or 1st local frequency reach a steady frequency 1.5ppm after setting pll setting data to change the frequency for 25khz www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 5/12 fin xf in gnd d0 vcc vp osc out osc in clk data le ps zc ld/f out p r vco lpf reference oscillator 21.25mhz up to 1200mhz +2.8v clk data le ld 2.2k ? 2.2k ? 2.2k ? 2.2k ? figure 4: pll ic control RMX2 has an internal pll frequency synthesizer as shown in figure 1. channel frequency is set by loading data directly into the registers of the controlling ic over a simple, 3 wire serial bus (interface pins clk, le, data). also RMX2 has a lock detect (ld) terminal that shows the lock status of the frequency. these signal lines are connected directly to the pll ic through a 2.2k ? resistor. the interface voltage of RMX2 is 2.8 v, so the control voltage must be the same. RMX2 comes equipped with a fujitsu mb15e03sl pll ic. please refer to the manual of the pll ic. http://www.fujitsu.com/downloads/micro/fme/pll/e421359.pdf the following is a supplementary description related to operation with RMX2. in this description, the same names and terminology as in the pll ic manual are used, so please read the manual beforehand. how to calculate the setting values for the pll register the pll ic manual shows that the pll frequency setting value is obtained with the following equation. () [] r f a n m f osc vco + = n > m 2 equation 1 f vco : output frequency of external voltage controlled oscillator (vco) n: preset divide ratio of binary 11-bit programmable counter (3 to 2,047) a: preset divide ratio of binary 7-bit swallow counter (0 a 127) f osc : output frequency of the reference frequency oscillator r: preset divide ratio of binary 14-bit programmable reference counter (3 to 16,383) m: preset divide ratio of the dual modulus prescaler (64 or 128) because of the circuitry used in the RMX2, the frequency programmed into the pll must be 21.7mhz below the desired channel frequency. there is no need to re-program when switching between transmit and receive modes. therefore the expected value of the frequency generated at vco (fexpect) is as below. fvco = fexpect = (fch ? 21.7mhz) equation 2 the pll generates channel frequencies as multiples of a 'comparison' frequency. this phase comparison frequency (fcomp) is made by dividing the frequency input to the pll from the reference oscillator by reference counter r. the RMX2 uses a 21.25 mhz tcxo for the reference clock fosc. fcomp can be either 12.5khz or 25 khz. the above equation 1 results in the following with n = m x n + a, where ?n? is the number for division. comp vco f n f = equation 3 RMX2-xxx-10 control pin name www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 6/12 comp vco f f n = note: r f f osc comp = equation 4 also, this pll ic operates with the following r, n, a and m relational expressions. comp osc f f r = equation 5 ? ? ? ? ? ? = m n int n int: integer portion of a division equation 6 () n m n a ? = equation 7 as an example, the setting value of rf channel frequency f ch 434.6750mhz can be calculated as below. conditions: channel center frequency: f ch = 434.6750mhz constant: offset frequency: f offset =21.7 mhz constant: reference frequency: f osc =21.25 mhz set 25 khz for phase comparison frequency f comp and 64 for prescaler value m the frequency of vco will be: f vco = f expect = f ch ? foffset = 434.675 ?21.7 = 412.975mhz dividing value ?n? is derived from equation 4 n = f vco / f comp = 412.975mhz/25khz = 16519 value ?r? of the reference counter is derived from equation 5. r = f osc /f comp = 21.25mhz/25khz = 850 value ?n? of the programmable counter is derived from equation 6. n = int (n/m) = int(16519/64) = 258 value ?a? of the swallow counter is derived from equation 7. a = n ? (m x n) = 16519 ? 64 x 258 = 7 the frequency of RMX2 is locked at a centre frequency f ch by inputting the pll setting values n, a and r obtained with the above equations as serial data. the above calculations are the same for the other frequencies. method of serial data input to the pll after the rf channel table plan is decided, the data needs to be allocated to the rom table and read from there or calculated with the software. together with this setting data, operation bits that decide operation of the pll must be sent to the pll. the operation bits for setting the pll are as follows. these values are placed at the head of the reference counter value and are sent to the pll. cs: charge pump current select bit cs = 0 1.5 ma select vco is optimised to 1.5 ma lds: ld/fout output setting bit lds = 0 ld select hardware is set to ld output fc: phase control bit for the phase comparator fc = 1 hardware operates at this phase www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 7/12 data 1 data st 1 data st 2 data nd 2 data nd clk le RMX2 terminal name #: t0,t5 >= 100 ns t1,t2,t6 >= 20 ns t3,t4 >= 30 ns #: keep the le terminal at a low level, w hen write the data to the shift resister. msb cs lds fc sw r14 r13 r1 16 14 13 12 11 10 15 cnt=1 invalid data n11 n10 n9 n8 n7 n6 a1 cnt=0 lsb figure 5: pll ic programming timing diagram the pll ic, which operates as shown in the block diagram in the manual, shifts the data to the 19-bit shift register and then transfers it to the respective latch (counter, register) by judging the cnt control bit value input at the end. clk [clock]: data is shifted into the shift register on the rising edge of this clock. le [load enable]: data in the 19-bit shift register is transferred to respective latches on the rising edge of the clock. the data is transferred to a latch according to the control bit cnt value. data [serial data]: you can perform either reference counter setup or programmable counter setup first. timing chart control timing in a typical application is shown in figure 3. initialisation of the radio is performed following power-up and successful reset of the controlling cpu. the fet switches controlling the radio module systems (controlled by rxsel and txsel) must be set to inactive (pin high or floating) to avoid unwanted emissions. the power supply to the radio module is then turned on. when the radio module is first powered, the pll internal registers are not yet set to meaningful values, and the vco circuit will be unstable. data transmission and reception is only possible 40 ms after the first set up data is sent to the pll. subsequent ?channel change? re-programming only takes 20 ms before data can be handled. changing channels must be carried out in the receive mode. if switching is performed in transmission mode, unwanted interference will be generated. if the module is switched to the receive mode when operating in the same channel, (a new pll setting is not necessary) it can receive data within 5 ms of switching *1 . for data transmission, if the rf channel to be used for transmission is set while still in receiving mode, data can be sent at 5 ms after the radio module is switched from reception to transmission *2 . check that the lock detect signal is ?high? 20 ms after the channel is changed. in some cases the lock detect signal becomes unstable before the lock is correctly detected, so it is necessary to note if processing of the signal is interrupted. *1: dc offset may occur due to frequency drift caused by ambient temperature change. customers are urged to verify operation at low temperature and nitiali their timing. *2: sending ?10101?..? preamble just after switching to transmission mode enables smoother operation of the data extraction circuit used by the receiver. for 9600 bps, a preamble of ?11001100? is effective. recommended preamble length: -10 c -+55c: 7 ms -20 c - +65 c (for operation exceeding the above range): 15 ms www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 8/12 # 3 5ms 5ms 5ms 5ms # 2 # 4 # 4 # 4 ch ch ch data 5 # data 6 # data 7 # # 1 cpj power on RMX2 power on data transmit lo rx select tx select cpu control ch change & data recovery timing states immediately after power comes on normal status no channel change figure 6: timing diagram for RMX2 #:1 reset control cpu #:5 40 ms later, the receiver can receive the data after changing the channel.. #:2 initialize the port connected to the module. #:6 10 to 20 ms later, the receiver can receive the data after changing the channel. #:3 supply pow er to the module after nitialising cpu. #:7 5 ms later, the data can be received if the rf channel is not chang ed. #:4 rfchannel change must be performed in receiving mode. www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 9/12 pll frequency setting data reference RMX2-433-10 : 433mhz european ism band (433.050 ? 434.790 mhz) parameter name value phase comparing frequency f comp [khz] 25 start channel frequency f ch [mhz] 433.0750 channel step frequency [khz] 25 number of channel 69 prescaler m 64 parameter name value reference frequency f osc [mhz] 21.25 offset frequency f offset [mhz] 21.7 : for data input : result of calculation : fixed vale parameter name value reference counter r 850 programmable counter n min. value 257 programmable counter n max. value 258 swallow counter a min. value 0 swallow counter a max. value 63 ch. no. channel frequency f ch expect frequency f expect lock frequency f vco (mhz) (mhz) (mhz) number of division n programmable counter n swallow counter a 0 433.0750 411.3750 411.3750 16455 257 7 1 433.1000 411.4000 411.4000 16456 257 8 2 433.1250 411.4250 411.4250 16457 257 9 3 433.1500 411.4500 411.4500 16458 257 10 4 433.1750 411.4750 411.4750 16459 257 11 5 433.2000 411.5000 411.5000 16460 257 12 6 433.2250 411.5250 411.5250 16461 257 13 7 433.2500 411.5500 411.5500 16462 257 14 8 433.2750 411.5750 411.5750 16463 257 15 9 433.3000 411.6000 411.6000 16464 257 16 10 433.3250 411.6250 411.6250 16465 257 17 11 433.3500 411.6500 411.6500 16466 257 18 12 433.3750 411.6750 411.6750 16467 257 19 13 433.4000 411.7000 411.7000 16468 257 20 14 433.4250 411.7250 411.7250 16469 257 21 15 433.4500 411.7500 411.7500 16470 257 22 16 433.4750 411.7750 411.7750 16471 257 23 17 433.5000 411.8000 411.8000 16472 257 24 18 433.5250 411.8250 411.8250 16473 257 25 19 433.5500 411.8500 411.8500 16474 257 26 20 433.5750 411.8750 411.8750 16475 257 27 21 433.6000 411.9000 411.9000 16476 257 28 22 433.6250 411.9250 411.9250 16477 257 29 23 433.6500 411.9500 411.9500 16478 257 30 24 433.6750 411.9750 411.9750 16479 257 31 25 433.7000 412.0000 412.0000 16480 257 32 26 433.7250 412.0250 412.0250 16481 257 33 27 433.7500 412.0500 412.0500 16482 257 34 28 433.7750 412.0750 412.0750 16483 257 35 29 433.8000 412.1000 412.1000 16484 257 36 30 433.8250 412.1250 412.1250 16485 257 37 31 433.8500 412.1500 412.1500 16486 257 38 32 433.8750 412.1750 412.1750 16487 257 39 33 433.9000 412.2000 412.2000 16488 257 40 www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 10/12 34 433.9250 412.2250 412.2250 16489 257 41 35 433.9500 412.2500 412.2500 16490 257 42 6 433.9750 412.2750 412.2750 16491 257 43 37 434.0000 412.3000 412.3000 16492 257 44 38 434.0250 412.3250 412.3250 16493 257 45 39 434.0500 412.3500 412.3500 16494 257 46 40 434.0750 412.3750 412.3750 16495 257 47 41 434.1000 412.4000 412.4000 16496 257 48 42 434.1250 412.4250 412.4250 16497 257 49 43 434.1500 412.4500 412.4500 16498 257 50 44 434.1750 412.4750 412.4750 16499 257 51 45 434.2000 412.5000 412.5000 16500 257 52 46 434.2250 412.5250 412.5250 16501 257 53 47 434.2500 412.5500 412.5500 16502 257 54 48 434.2750 412.5750 412.5750 16503 257 55 49 434.3000 412.6000 412.6000 16504 257 56 50 434.3250 412.6250 412.6250 16505 257 57 51 434.3500 412.6500 412.6500 16506 257 58 52 434.3750 412.6750 412.6750 16507 257 59 53 434.4000 412.7000 412.7000 16508 257 60 54 434.4250 412.7250 412.7250 16509 257 61 55 434.4500 412.7500 412.7500 16510 257 62 56 434.4750 412.7750 412.7750 16511 257 63 57 434.5000 412.8000 412.8000 16512 258 0 58 434.5250 412.8250 412.8250 16513 258 1 59 434.5500 412.8500 412.8500 16514 258 2 60 434.5750 412.8750 412.8750 16515 258 3 61 434.6000 412.9000 412.9000 16516 258 4 62 434.6250 412.9250 412.9250 16517 258 5 63 434.6500 412.9500 412.9500 16518 258 6 64 434.6750 412.9750 412.9750 16519 258 7 65 434.7000 413.0000 413.0000 16520 258 8 66 434.7250 413.0250 413.0250 16521 258 9 67 434.7500 413.0500 413.0500 16522 258 10 68 434.7750 413.0750 413.0750 16523 258 11 www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd RMX2-433-10 data sheet pa ge 11/12 RMX2-458-10 : 458mhz uk srd band (458.525 ? 459.175 mhz) parameter name value phase comparing frequency f comp [khz] 25 start channel frequency f ch [mhz] 458.5250 channel step frequency [khz] 25 number of channel 27 prescaler m 64 parameter name value reference frequency f osc [mhz] 21.25 offset frequency f offset [mhz] 21.7 : for data input : result of calculation : fixed vale parameter name value reference counter r 850 programmable counter n min. value 273 programmable counter n max. value 273 swallow counter a min. value 1 swallow counter a max. value 27 ch no. channel frequency f ch expect frequency f expect lock frequency f vco (mhz) (mhz) (mhz) number of division n programmable counter n swallow counter a 0 458.5250 436.8250 436.8250 17473 273 1 1 458.5500 436.8500 436.8500 17474 273 2 2 458.5750 436.8750 436.8750 17475 273 3 3 458.6000 436.9000 436.9000 17476 273 4 4 458.6250 436.9250 436.9250 17477 273 5 5 458.6500 436.9500 436.9500 17478 273 6 6 458.6750 436.9750 436.9750 17479 273 7 7 458.7000 437.0000 437.0000 17480 273 8 8 458.7250 437.0250 437.0250 17481 273 9 9 458.7500 437.0500 437.0500 17482 273 10 10 458.7750 437.0750 437.0750 17483 273 11 11 458.8000 437.1000 437.1000 17484 273 12 12 458.8250 437.1250 437.1250 17485 273 13 13 458.8500 437.1500 437.1500 17486 273 14 14 458.8750 437.1750 437.1750 17487 273 15 15 458.9000 437.2000 437.2000 17488 273 16 16 458.9250 437.2250 437.2250 17489 273 17 17 458.9500 437.2500 437.2500 17490 273 18 18 458.9750 437.2750 437.2750 17491 273 19 19 459.0000 437.3000 437.3000 17492 273 20 20 459.0250 437.3250 437.3250 17493 273 21 21 459.0500 437.3500 437.3500 17494 273 22 22 459.0750 437.3750 437.3750 17495 273 23 23 459.1000 437.4000 437.4000 17496 273 24 24 459.1250 437.4250 437.4250 17497 273 25 25 459.1500 437.4500 437.4500 17498 273 26 26 459.1750 437.4750 437.4750 17499 273 27 note : in the 458mhz srd band in the uk, channel frequencies 458.825mhz, 458.8375mhz and 458.900mhz are reserved for alarm usage, and should not be used for general telemetry applications www.datasheet.co.kr datasheet pdf - http://www..net/
radiometrix ltd hartcran house 231 kenton lane harrow, middlesex ha3 8rp england tel: +44 (0) 20 8909 9595 fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com copyright notice this product data sheet is the original work and copyrighted property of radiometrix ltd. reproduction in wholeor in part must give clear acknowledgement to the copyright owner. limitation of liability the information furnished by radiometrix ltd is believed to be accurate and reliable. radiometrix ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. radiometrix ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. this data sheet neither states nor implies warranty of any kind, including fitness for any particular application. these radio devices may be subject to radio interference and may not function as intended if interference is present. we do not recommend their use for life critical applications. the intrastat commodity code for all our modules is: 8542 6000. r&tte directive after 7 april 2001 the manufacturer can only place finished product on the market under the provisions of the r&tte directive. equipment within the scope of the r&tte directive may demonstrate compliance to the essential requirements specified in article 3 of the directive, as appropriate to the particular equipment. further details are available on the office of communications (ofcom) web site: http://www.ofcom.org.uk/radiocomms/ifi/ information requests ofcom riverside house 2a southwark bridge road london se1 9ha tel: +44 (0)845 456 3000 or 020 7981 3040 fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk european radiocommunications office (ero) peblingehus nansensgade 19 dk 1366 copenhagen tel. +45 33896300 fax +45 33896330 ero@ero.dk www.ero.dk www.datasheet.co.kr datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of RMX2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X